BWQVX - HYDRECON 186 ES

Product Identification

Product ID:HYDRECON 186 ES
MSDS Date:01/27/1992
FSC:9350
NIIN:00N057549
MSDS Number: BWQVX

Responsible Party
J H FRANCE REFRACTORIES CO
CLARENCE RD
SNOW SHOE, PA 16874
US

Emergency Phone: 814-387-6811

Info Phone: 814-387-6811

Cage: IO330

Contractor
J H FRANCE REFRACTORIES CO
SNOW SHOE, PA 16874 US

Telephone: 814-387-6811

Cage: IO330

Ingredients

KAOLIN; (CALCINED CLAY)

CAS: 66402-68-4

Fraction By Weight: 80%

OSHA PEL N/K

ACGIH TLV: 5 MG/M3 (MFR)


CEMENT BINDER; (CEMENT)

CAS: 65997-16-2

Fraction By Weight: 20%

OSHA PEL N/K

ACGIH TLV: 10 MG/M3 (MFR)


SILICA; (FREE SILICA)

CAS: 60676-50-0

OSHA PEL N/K

ACGIH TLV: 0.1 MG/M3 (MFR)


LIME

CAS: 1332-69-0

OSHA PEL N/K

ACGIH TLV: N/K


SILICA, CRYSTALLINE - QUARTZ

CAS: 14808-60-7

RTECS: VV7330000

OSHA PEL SEE TABLE Z-3

ACGIH TLV: 0.1 MG/M3 RDUST;9495

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:MAY CAUSE SERIOUS PULMONARY DISORDERS
OVER A LONG PERIOD OF DUST INHALATION. PRODUCT CONTAINS LIME WHICH
MAY CAUSE EYE OR SKIN IRRITATIONS DUE TO THE BASICITY OF LIME.
WARNING:IARC HAS CLASSIFIED SILI CA AS A CLASS 2A CARCINOGEN. IN
THEIR OPINION THERE IS SUFFICIENT EVIDENCE TO ANIMALS & LIMITED
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:CRYSTALLINE SILICA (QUARTZ)- IARC GROUP
2A, SUP 7, P 165, 1987; ANTICIPATED CARCINOGEN, NTP 7TH ANN REPORT,
1994.
Effects of Overexposure:HLTH HAZ:EVIDENCE TO HUMANS FOR CARCINOGENICITY
OF CRYSTALLINE SILICA.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:CONSULT W/MD. INGEST:CALL MD IMMEDIATELY . INHAL:REMOVE TO
FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF RESP) .
EYES:IMMEDIATELY FLUSH W/POTABLE WATER FOR A MINIMUM OF 15 MINUTES,
SEEK ASSI STANCE FROM MD . SKIN:FLUSH W/COPIOUS AMOUNTS OF WATER.
CALL MD .

Fire Fighting

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:EXPLOSIVE TENDENCY:CARE MUST BE EXERCISED
DURING INITIAL FIRING. CONSULT MFR FOR FURTHER INFO.

Accidental Release

Spill Release Procedures:IF PRODUCT IS DRY, USE DRY CLEAN-UP
PROCEDURES; AVOID DUSTING. COLLECT IN CONTAINERS OR BAGS. IF REUSE
OF RECYCLING IS NOT POSSIBLE, MATERIAL MAY BE DISPOSED OF AT A
SANITARY LANDFILL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:HANDLING EQUIPMENT SHOULD BE DESIGNED
TO KEEP AIRBORNE DUST TO A MINIMUM FOR WORKER COMFORT.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:WHERE EXPOSURE LIMIT IS OR MAY BE EXCEEDED, USE
NIOSH/MSHA APPROVED RESPIRATORY PROCTECTION. SELECTION OF
APPROPRIATE RESPIRATOR SHOULD BE BASED ON ACTUAL OR POTENTIAL
CONTAMINANTS & THEIR CONCENTRATI ONS PRESENT.
Ventilation:USE W/ADEQUATE VENTILATION TO MEET EXPOSURE LIMITS (TLV).
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Spec Gravity:125 PCF
Solubility in Water:NOT SOLUBLE
Appearance and Odor:GREY TO BROWN, DRY-GRANULAR MIXTURE; NON ODOROUS.

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE.

Disposal

Waste Disposal Methods:DISPOSE OF I/A/W FEDERAL, STATE & LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.